Grease filter G2 EU2 Iso Coarse 30% 500x500x70 mm frame and metal insert
MF/FAT/OC G2 ISO COARSE 30% 500x500x70 mm
Air filtration efficiency Grease filter G2 EU2 Iso Coarse 30% 500 x 500 x 70 mm metal frame
Grease filter G2 EU2 Iso Coarse 30% 500x500x70 mm frame and metal insert
MF/FAT/OC G2 ISO COARSE 30% 500x500x70 mm
Air filtration efficiency Grease filter G2 EU2 Iso Coarse 30% 500 x 500 x 70 mm metal frame

Grease filter G2 EU2 Iso Coarse 30% 500 x 500 x 70 mm frame and metal insert

Grease filter in a galvanized metal frame for kitchen hoods and gastronomic mechanical ventilation systems, dimensions 500x500x70 mm, filtration class G2 eu2 with an iso coarse efficiency of 30%. Using an insert of a properly interwoven fabric made of galvanized steel. Metal filter highly effective, unrivaled in capturing volatile pollutants, including fats, thanks to the appropriate weave of metal knitted fibers, the structure of which allows for regeneration by washing, thus allowing for multiple and long-term use of the metal air filter. Guaranteeing very effective and efficient air filtration from fats in ventilation exhausts in catering facilities. Successfully used in most industrial kitchen hoods and more.

Production 6 - 10 working days then shipping
zł219.00
Tax included

 

Metal filter for filtration of fats in kitchen hoods of gastronomic facilities

Iso Coarse 30% 500 x 500 x 70 mm

Manufacturer Name Murano Feniks: MF/FAT/OC G2 ISO COARSE 30% 500x500x70 mm

Metal filter with a durable and durable structure. In a frame made of galvanized sheet, it is used for filtration of fats in kitchen hoods of gastronomic facilities. The filter cartridge is made of high-quality metal knitted fabric made of galvanized steel. A special weave of metal threads forming a dense labyrinth ensures maximum efficiency of catching grease particles, also increasing dust absorption. Thanks to the appropriate design, the grease filter provides unrivaled separation of grease from the filtered air. It is characterized by high efficiency and low pressure drop. The advantages also include the multiple possibility of regeneration, which can be done by washing without affecting its properties due to the fact that it is resistant to moisture. Metal filters are successfully used in various types of cooker hoods used in gastronomy to remove fumes generated during cooking, frying or baking various dishes. Kitchen fumes passing through the network of metal fibers consisting of many layers are precipitated from the air and thus they are trapped on the filter. As a result of the heated air colliding with the filter surface at a lower temperature, particles heavier than air, i.e. fat and other impurities, are deposited on it. Purified in this way, the air consisting of non-condensed water vapor and aromatic substances moves further through a pipe to the chimney or ventilation operating in the exhaust mode, the absorber. We recommend cleaning grease filters at least once a month because they retain not only grease but also other impurities such as dust and insects. Metal filters that are not regularly serviced can be too greasy, thus leading to less air exchange through reduced openings in the filter. This state of affairs contributes to an increase in the volume of the extractor during the operation of the extractor and reduces the amount of air passed through, leading to a reduction in the extraction capacity of the extractor hood and the absorber. The reason for replacing the metal filter with a new one is mechanical damage that prevents effective air purification. Our grease filters are made according to the latest filtration standards. They meet the G2 filtration class and their efficiency is Iso Coarse 30%. The grease filter, dimensions 500x500x70 mm, allows capturing 30% of coarse impurities from the air. It is a pre-filter for air filtration in cooker hoods operating in exhaust or absorber mode. They are used in single-family houses, hospitals, hotels and restaurants. In addition, knitted metal filters, apart from ventilation and air conditioning, are also used in machines, silencers and separators.

Technical data:

Grease filter G2 / EU2 Iso Coarse 30%

Dimensions:

Width: 500 mm

Length: 500 mm

Frame depth: 70 mm

Parameters:

• Filter material: galvanized steel knit

• Frame type: galvanized sheet

• Filter class according to EN 779: 2012: G2

• Filter class according to ISO 16890: Iso Coarse 30%

• Maximum working temperature: <300 ° C

• Permissible relative humidity: <100%

• Efficiency: ~ 95%

Filter material:

• High-quality knit made of stainless steel, woven in an appropriate way so as to maximize the efficiency of catching fat particles and ensuring increased dust absorption.

Building:

• Tight and durable construction.

• Metal knit placed in a stainless steel frame. On both sides secured by durable nets ensuring the stability of the structure.

Application:

• Thanks to its design, it is unbeatable in the separation of grease from filtered air. Used in cooker hoods, used in catering, hotels, hospitals, and single-family houses. The durable structure allows for multiple regeneration of the filter by washing with a jet of water under pressure, which significantly reduces operating costs. They are also used in silencer and separator machines

Properties:

• High efficiency

• Low pressure drop

• Durable construction

• Low operating costs

• Easy regeneration

• Long service life

• Moisture resistant

• High temperature resistance

• Standard and special sizes

• Filters are made in accordance with the requirements of the ISO 9001 Quality Management System, which ensures that the product maintains the highest quality at all times.

The air supplied by the ventilation, air conditioning and recuperation systems is as clean as the filters that clean them, and therefore the quality of the filters, their reliability and durability have a huge impact on the operation of the entire ventilation system and the quality of the air supplied by it.

We reserve the right to make changes to the technical specifications at any time without prior notice, as a result of continuous product improvement.

General information on filters and their replacement in the recuperator

Selection of filters according to expectations and needs, how to distinguish them from each other?

Every user of a mechanical ventilation system, commonly known as recuperation, used to struggle with the choice of air filters for their device. Don't know where and where to buy recuperator filters. It is not an easy task, so we are here to help. Each filter should have a rating label specifying the filtration class in accordance with the currently adopted standards, i.e. EN 779: 2012 and ISO 16890. Standard EN 779 divides filters into several groups marked with letters, i.e. G (coarse), M (medium), F (accurate), E, ​​H, U (highly effective - used in hospitals, military industry, etc.). Next to the letters there are numbers indicating the filtration efficiency in a given group and the entire scale ranging from 1-17. To evaluate the filtration efficiency in the EN 779 standard, an aerosol with a uniform particle size, ie 0.4 µm for filtration classes M5 - F9, is used. For coarse filters G1 - G4 there is a dust called ASHRAE consisting of fine mineral dust (72%), carbon black (23%) and cotton fibers (5%), these particles are close to 80 µm. The highly effective EPA, Hepa, Ulpa filters are tested with a paraffin oil mist aerosol, sodium chloride aerosol, DEHS aerosol (diethylhexyl sebacate polydisperse aerosol) or DOP (octyl phthalate monodisperse aerosol).

Coarse filters belong to this group of filtration classes G1 / EU1, G2 / EU2, G3 / EU3, G4 / EU4

They are very good at filtering basic air pollutants such as leaves, insects, hair, sand, ash, plant spores. They are ineffective in the filtration of pollen, fungal spores, fine dust and smog.

Medium filters, which include the filtration classes M5 / EU5, M6 / EU6

As the name implies, the averages are in the middle between the coarse and fine filters, which results in a high level of coarse dirt filtration and the basic filtration of fine filters. Medium filters do a good job of filtering pollen, bacteria and cement dust, which is very fine, but they do not stop smog that is so harmful to health.

Fine filters marked with filtration classes F7 / EU7, F8 / EU8, F9 / EU9

These are the best and most accurate filters that can be used in home recuperation. Fine filters are characterized by very high filtration efficiency of soot, tobacco smoke, oil smoke, bacteria with carrier particles, but also in the case of class F9 smog and allergens, i.e. all pollen. We recommend installing filters from the exact class only on the supply air due to the greater resistance. On the exhaust, we suggest using filters made in lower filtration classes, ie G4 / EU4, M5 / EU5, which will allow you to take care of the environment by reducing electricity consumption and reduce the frequency of recuperator filters replacement.

The latest ISO 16890 standard has been in force since 2018. It consists in subjecting filters to filtration tests of particles of various sizes that are part of the DEHS aerosol (diethylhexyl sebacate polydisperse aerosol). DEHS consists of particles with a diameter of 0.2-3 micrometers. The filtration efficiency is not expressed in numbers but as a percentage, so we are fully aware of what part of the particles will be filtered from the air by our new coarse, medium or fine filter. The ISO 16890 standard defines four new groups of filters based on the size of dust particles, allowing for simpler and more practical selection of filters according to the expectations and needs of customers. It also allows you to precisely determine the filtration efficiency of a given filter material used in the production of the filter. How does the buyer know where the most effective filter is in the filtration of the most harmful particles.

• ISO Coarse: estimates for the separation of new ISO A2 dust (natural dust);

• PM10: for particle sizes ≤ 10 μm;

• PM2.5: for particle sizes ≤ 2.5 μm;

• PM1: for particle sizes ≤ 1 µm.

The described standard of filtration was introduced in order to more accurately present the users of mechanical ventilation with the level of filtration efficiency of filters in relation to the size and amount of particles retained by them that have a harmful effect on the body. We mean mainly PM2.5 and PM1 particles. Below the size of harmful dusts and their ability to penetrate the body.

• Particles larger than 10 µm (ISO Coarse) are retained by the upper respiratory tract and are not inhaled;

• Particles smaller than 10 µm in diameter (PM10) can penetrate the bronchi;

• Particles smaller than 2.5 µm (PM2.5) can penetrate the alveoli;

• Particles with a diameter below 1 µm (PM1) can penetrate the vesicle-capillary barrier and get into the blood, this group includes smog particles.

When buying recuperator filters that meet the above-described ISO 16890 standard, which comply with the currently applicable EU regulations and are admitted to trading. Should have the ISO 16890 filtration standard specified in the product description. The filter rating label, in addition to the size, should also include the filtration standard ISO 16890 and graphic information showing the direction of air flow, e.g. an arrow. The reverse assembly of the filters from the air flow results in a very quick wear of the filter for mechanical ventilation with heat recovery, called recuperation, because the filter is a sieve that thickens towards the air outlet and filters smaller and smaller particles along with the condensation.

Which air filters should be installed on the supply and which ones on the exhaust and the choice of the filtration class?

It is best to install an air filter from the fine group (F7 - ePM1, F8 - ePM1, F9 - ePM1) on the supply air, i.e. the air flowing into the house. This will filter out the most harmful particles of smog and other unnatural dusts. At the exhaust, we suggest installing coarse or medium filters (G4 - ISO Coarse, M5 - ePM-10). The air flowing into the house has been cleaned by a filter mounted on the supply, so there is no need to install filters with the same or higher filtration efficiency on the exhaust, i.e. the removed air from the building. Installation of fine filters on the supply and exhaust air will increase electricity consumption, air resistance and faster filter wear.

Which filter frame to choose?

It is an individual matter. Metal and plastic frames are less susceptible to mechanical damage during transport, they withstand maximum humidity and during assembly they allow for a reliable replacement without fear of damage. The cardboard frame is more delicate, but its important feature is environmental friendliness during disposal.

Replacing recuperator air filters - how to do it yourself?

• Prepare the air handling unit for filter replacement (disable or activate the filter replacement mode);

• Open the inspection hatch or flaps;

• Take out the old filters;

• Clean the guides;

• Insert new filters with the arrows in the air flow direction (pay attention to the filtration class, a higher class can be used on the supply air);

• Restart the device by restarting it.

I am looking for a filter for my mechanical ventilation, house, apartment, recuperator - where can I order such filters?

• Write to us, we will present an offer and produce filters.

• In the e-mail, please provide the brand and model of the device as well as the dimensions of the currently installed air filters.

• And in the attachments you can attach photos of the filters currently installed and the rating plate of the device.

We make air filters for every air handling unit, recuperation and mechanical ventilation systems. On this page you will find filters that will meet your expectations, because when you are looking for an economical solution, we have them, and when you want to fully protect the health of your household, we also offer such filters.

List of air filter dimensions
500 * 500 * 70 mm
Type of air filter
Metal
The range of filtration efficiency
Anti-fatty
The filter material used
Knitted metal
Filter class EN779: 2012
EU2 / G2
Filtration standard DIN EN ISO 16890
Iso coarse 30%
Filter frame type
Galvanized steel
Estimated operating time
Repeated use - Regeneration through cleaning and washing
PKWiU / CN
8421999099
MF/FAT/OC G2 ISO COARSE 30% 500x500x70 mm

Confirming in the selection of a product, we encourage you to contact us by phone or e-mail, you can also use the tips included in the categories. All products are delivered directly from our warehouse and shipped according to the scheduled delivery date. We ship products that are in stock within 24 hours. Filters made to order 7 working days. If you do not have the filters you need in our store, please email us with the necessary information. We will prepare an offer, once you accept it, we will make the products you need.

No reviews
Product added to wishlist
Product added to compare.

iqitcookielaw - module, put here your own cookie law text